Experimental Investigations on Thermo-hydraulic Performance due to Flow- Attack- Angle in Multiple V-ribs with Gap in a Rectangular Duct of Solar Air Heaters

Main Article Content

Anil Kumar
R.P. Saini
J.S. Saini

Abstract

An experimental investigation was carried out to study the effect of artificial roughness, in the form of multi v-shaped ribs with gap on one heated wall of a rectangular solar air heater duct, on heat transfer (Nusselt number) and friction loss (friction factor). The artificially roughened duct had a width to height ratio (W/H) of 12, relative roughness width ratio (W/w) of 6, relative roughness pitch (P/e) of 10, relative roughness height (e/D) of 0.0433, relative gap width (g/e) of 1.0, relative gap distance (Gd/Lv) of 0.69, while the angle of attack (α) was varied from 30° to 75°. The heat transfer and friction characteristics of the duct were compared with those of a smooth duct under similar experimental conditions. It was found that there was a significant effect on the Nusselt number and friction factor when the angle of attack was changed.

Article Details

Section
Articles